Door guard keypad manual






















Standalone Keypad Installation / Programming Manual This equipment is designed to be installed and serviced by security and lock industry professionals. Contents door loop doesn’t need to be closed for the REX function to operate, by default, but setting option 8 to 0 under command 30, programs. Door Guard Series Keypads offer reliability in a cost-effective solution anywhere access control is desired. These keypads are the perfect choice for controlling electric locking devices, security systems and automatic operators. Door Guards accept power from a 12/24 VAC/DC supply. No separate programmer is necessary. The key pad extends 9/16" from the wall when mounted flush on a 1-gang . monitored zone types (e.g., door, hallway, elevator, and automatic door). With single conditioning, if an active Tag enters a monitored zone, the system will detect the Tag and an egress alarm will be generated. To clear this alarm, remove the Tag from the zone and enter a valid code into the zone Keypad. Double Conditioning – Door and Hallway.


KEYPAD ACTIVE OUTPU T. The Command and Control Series Door-Gards can be. programmed to energize a voltage output whenever a key i s. touched. This can be used to turn on accessories such a s. lights, CCTV camera, or notify a guard. This output is no t. available if the IEI Printer Interface is used. AUTO-ENTR Y. Form-C relay will energize if the door is opened without a valid user entry or egress input. This output can be pr-o grammed to energize for up to 15 minutes or latch. It can be reset by a valid code entry. PROPPED DOOR RELAY Programming a 1 to 15 minute open door time allows the Door-Gard to alert you to a propped door by energizing a 1 Amp. 16 – Keypad Active Output 17 – Door Bell Output* 18 – REX Input Active 19 – Door Loop Input Active Note: The keypad is equipped with only two relays. The Output Expansion Module (EX) is required to use additional outputs. *Note: The Door Bell Output also works in both Front End Modes. Disable Virtual Output 10 # virtual output # 0.


disarm alarm after inputting passcode. This keypad can also connect to an automatic door lock. KIT CONTENTS. Keypad x 1. AAA V battery x 3. Screws x 4. DIGITAL ACCESS CONTROL KEYPAD. DC60SS, DC50SS, DC50FS PTDC50M. Programming Installation Manual. FOR ELECTRIC LOCK, INTER-LOCK. PLEASE READ THIS MANUAL BEFORE BEGINNING THE INSTALLATION OF A SECURE CARE SYSTEM. (Door contact, nurse station, exit panel power, magnetic lock, etc.

0コメント

  • 1000 / 1000